Protect your battery and preserve cranking power by automatically disconnecting non-essential loads; 12/24V auto-ranging.
Product Details
Protect Your Battery:
Disconnects non-essential loads before deep discharge to prevent damage and preserve starting power.
Multiple Current Ratings:
Choose between 65A–220A and Standard or Bluetooth; size to peak load, pick Bluetooth for easier programming.
Spark-Free MOSFET Switching:
Ignition proof design uses solid-state switches for spark-free operation and no relay wear.
Wide Voltage Support:
Auto-ranging operation handles 6-35 VDC systems with integrated over-voltage protection.
Smart Protective Delays:
Alarm and disconnect are time delayed to avoid false trips, with a short-circuit proof 50 mA alarm output.
Lithium-Friendly Control:
Offers a Li-ion specific setting, VE.Bus BMS control mode, and use as a charger-to-battery interrupter.
Tech Specs
Voltage
6-35 VDC
System Voltage
12/24V auto ranging
Alarm Activation Delay
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.
Load Disconnect Delay
The load will be disconnected 90 seconds after the alarm has been activated.
Reconnect Delay
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.
Current Rating
65A, 100A, or 220A
Over Voltage Disconnect
Bluetooth Capable: load disconnects whenever DC voltage exceeds 16.3V or 32.6V; Standard: load disconnects whenever DC voltage exceeds 16V or 32V.
Alarm Output
Short-circuit proof open collector output to negative rail; max. current 50 mA.